{"title":"FMC un-managed series fiber chassis","description":"\u003cp\u003e\u003cspan\u003eThe FMC chassis series are simple and small fiber rack mount chassis solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFMC chassis accommodate up to 17 FMC unmanaged fiber media converters and offer a single AC or DC power supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe chassis also includes a ventilation fan. The 17 slot chassis are 19\" rack mountable with options for 23\" rack mounting.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"fmc-ch17-aa-17-slot-fiber-chassis-with-dual-redundant-ac-power-and-fans","title":"FMC-CH17-AA - 17 slot fiber chassis with dual redundant AC power and fans","description":"\u003cp\u003e\u003cb\u003e\u003cspan\u003eProduct description\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFMC-CH17 series is one of the newest and most cost effective fiber aggregation solution. The FMC-CH17-AA is identical to FMC-CH17-AC but provides dual redundant AC power supplies.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe chassis has only 2U and can accommodate 17 units of FMC series media converters. The 17 slot chassis is designed to fit a 19\" wide telco rack system, placing up to 17 fiber media converters or VDSL2 modems on just 2U space height.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eStructure of FMC chassis is simple and straightforward. There are two AC switching power supplies with 90V-240V input and redundancy function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThere are no centralized management features, however, the FMC series of media converters support many features like \u003c\/span\u003e\u003cb\u003eFEF\u003c\/b\u003e\u003cspan\u003e(\u003c\/span\u003e\u003cb\u003eFar-End-Fault\u003c\/b\u003e\u003cspan\u003e) signaling and \u003c\/span\u003e\u003cb\u003eLFP\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cb\u003eLink-Fault-Pass\u003c\/b\u003e\u003cspan\u003e through) function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMedia converters are switching type, store-and-forward mechanism, and are able to work Half\/Full Duplex mode.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe FMC-CH17-AA is a perfect choice for small aggregation nodes in a fiber network environment. Up to 17 fiber media converters can be put together in a chassis and benefit of redundant power supplies, saving precious space in the data networking design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdditional information on FMC-CH17-AA chassis:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/fmc-ch17-datasheet.pdf?v=1742444083\" target=\"_blank\" rel=\"noopener\"\u003ePDF Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/fmc-ch17-manual.pdf?v=1742444083\" target=\"_blank\" rel=\"noopener\"\u003ePDF Installation Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":13775450931298,"sku":"FMC-CH17-AA","price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/FMCCH172.jpg?v=1536255362"},{"product_id":"lfc-ch12-ac-12-slot-fiber-chassis-with-one-ac-power-supply-and-fans-for-lfc-series-converters","title":"LFC-CH12-AC - 12 slot fiber chassis with one AC power supply and fans (for LFC series converters)","description":"\u003cp\u003eLFC-CH12-AC - 12 slot fiber chassis with one AC power supply and fans (for LFC series converters)\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: The LFC-CH12-AC is an empty chassis for LFC series media converters. 10G, Gigabit and Fast Ethernet media converters all can go into the LFC-CH12 chassis.\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003eProduct description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLFC-CH12 series are the most cost effective and highest density fiber aggregation solution.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eAll LFC-CH12 chassis have only 1RU and can accommodate 12 units of LFC series media converters. The 12 slot chassis is designed to fit a 19\" wide telco rack system, placing up to 12 fiber media converters for 10G, Gigabit or Fast Ethernet speed in just 1RU of space height.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLFC chassis are simple and straightforward. There are two bays for power supplies which can be populated and swapped independently under operation. The LFC-CH12-AC comes with a single AC switching power supply with 90V-240V input.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThere are no centralized management features, however, the LFC series of media converters support many features like \u003c\/span\u003e\u003cstrong\u003eLFP\u003c\/strong\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cstrong\u003eLink-Fault-Pass\u003c\/strong\u003e\u003cspan\u003e through) functions and forced speed and flow settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMedia converters are switching type, store-and-forward mechanism, and are able to work Half\/Full Duplex mode but most of them can also be set in transparent converter mode (no packet switching) for minimum latency.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe LFC-CH12 series are the perfect choice for High density nodes in a fiber network environment. Up to 12 fiber media converters can be put together in a 1RU chassis (24 converters in 2RU) with choice of redundant power supplies and saving precious space in the data networking design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdditional information on LFC-CH12-AC chassis:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/LFC-CH12-datasheet.pdf?v=1742443805\" target=\"_blank\"\u003e\u003cspan\u003eProduct Specification Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/LFC-CH12-manual_Letter.pdf?v=1742443804\" target=\"_blank\"\u003e\u003cspan\u003eProduct Installation Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":39623168688226,"sku":"LFC-CH12-AC","price":248.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/LFC-CH12-AC.webp?v=1742443869"},{"product_id":"lfc-ch12-ad-12-slot-fiber-chassis-with-redundant-ac-100-240v-and-dc-36-72v-power-supplies-and-fans-for-lfc-series-converters","title":"LFC-CH12-AD - 12 slot fiber chassis with redundant AC 100-240V and DC 36-72V power supplies and fans (for LFC series converters)","description":"\u003cp\u003eLFC-CH12-AD - 12 slot fiber chassis with redundant AC 100-240V and DC 36-72V power supplies and fans (for LFC series converters)\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: The LFC-CH12-AD is an empty chassis for LFC series media converters. 10G, Gigabit and Fast Ethernet media converters all can go into the LFC-CH12 chassis.\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003eProduct description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLFC-CH12 series are the most cost effective and highest density fiber aggregation solution.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eAll LFC-CH12 chassis have only 1RU and can accommodate 12 units of LFC series media converters. The 12 slot chassis is designed to fit a 19\" wide telco rack system, placing up to 12 fiber media converters for 10G, Gigabit or Fast Ethernet speed in just 1RU of space height.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLFC chassis are simple and straightforward. There are two bays for power supplies which can be populated and swapped independently under operation. The LFC-CH12-AD comes with two redundant power supplies: one AC 100-240V  and one DC 36-72V input. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThere are no centralized management features, however, the LFC series of media converters support many features like \u003c\/span\u003e\u003cstrong\u003eLFP\u003c\/strong\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cstrong\u003eLink-Fault-Pass\u003c\/strong\u003e\u003cspan\u003e through) functions and forced speed and flow settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMedia converters are switching type, store-and-forward mechanism, and are able to work Half\/Full Duplex mode but most of them can also be set in transparent converter mode (no packet switching) for minimum latency.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe LFC-CH12 series are the perfect choice for High density nodes in a fiber network environment. Up to 12 fiber media converters can be put together in a 1RU chassis (24 converters in 2RU) with choice of redundant power supplies and saving precious space in the data networking design\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdditional information on LFC-CH12-AD chassis:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PDF\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" alt=\"\" width=\"16\" height=\"16\" border=\"0\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/LFC-CH12-datasheet.pdf?v=1742443805\" target=\"_blank\"\u003ePDF Datasheet\u003c\/a\u003e\u003cspan\u003e; \u003c\/span\u003e\u003cimg title=\"PDF\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" alt=\"\" width=\"16\" height=\"16\" border=\"0\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/LFC-CH12-manual_Letter.pdf?v=1742443804\" target=\"_blank\"\u003ePDF Installation Manual\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/LFC-CH12-ACIM.pdf?v=1646790231\"\u003e\u003cspan\u003eProduct Installation Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":39624062926946,"sku":"LFC-CH12-AD","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/LFC-CH12-AC_800d51e6-b555-4958-9552-22c2dba20443.webp?v=1742444499"},{"product_id":"lfc-ch12-dd-12-slot-fiber-chassis-with-redundant-dc-36-72v-power-supplies-and-fans-for-lfc-series-converters","title":"LFC-CH12-DD - 12 slot fiber chassis with redundant DC 36-72V power supplies and fans (for LFC series converters)","description":"\u003cp\u003eLFC-CH12-DD - 12 slot fiber chassis with redundant DC 36-72V power supplies and fans (for LFC series converters)\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: The LFC-CH12-DD is an empty chassis for LFC series media converters. 10G, Gigabit and Fast Ethernet media converters all can go into the LFC-CH12 chassis.\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003eProduct description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLFC-CH12 series are the most cost effective and highest density fiber aggregation solution.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eAll LFC-CH12 chassis have only 1RU and can accommodate 12 units of LFC series media converters. The 12 slot chassis is designed to fit a 19\" wide telco rack system, placing up to 12 fiber media converters for 10G, Gigabit or Fast Ethernet speed in just 1RU of space height.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLFC chassis are simple and straightforward. There are two bays for power supplies which can be populated and swapped independently under operation. The LFC-CH12-DD comes with two redundant power supplies: both DC 36-72V input.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThere are no centralized management features, however, the LFC series of media converters support many features like \u003c\/span\u003e\u003cstrong\u003eLFP\u003c\/strong\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cstrong\u003eLink-Fault-Pass\u003c\/strong\u003e\u003cspan\u003e through) functions and forced speed and flow settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMedia converters are switching type, store-and-forward mechanism, and are able to work Half\/Full Duplex mode but most of them can also be set in transparent converter mode (no packet switching) for minimum latency.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe LFC-CH12 series are the perfect choice for High density nodes in a fiber network environment. Up to 12 fiber media converters can be put together in a 1RU chassis (24 converters in 2RU) with choice of redundant power supplies and saving precious space in the data networking design.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdditional information on LFC-CH12-DD chassis:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/LFC-CH12-datasheet.pdf?v=1742443805\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eProduct Specification Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/LFC-CH12-manual_Letter.pdf?v=1742443804\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eProduct Installation Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":39624064761954,"sku":"LFC-CH12-DD","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/LFC-CH12-AC_bab0f76a-b8dc-48ca-a3dc-f152fb66459f.webp?v=1742444625"},{"product_id":"t-fmc-1800-ad-gigabit-18-port-sfp-managed-patching-hub-10-100-1000base-tx-to-100-1000base-x-sfp-snmp-usb-rack-19-ac-dc48-power","title":"FMC-1800-AD - Gigabit 18 port SFP managed patching hub, 10\/100\/1000Base-TX to 100\/1000Base-X SFP, SNMP, USB, rack 19\", AC \u0026 DC48 power","description":"\u003cp\u003eFMC-1800-AD - Gigabit 18 port SFP managed patching hub, 10\/100\/1000Base-TX to 100\/1000Base-X SFP, SNMP, USB, rack 19\", AC \u0026amp; DC48 power.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003eSFPs are NOT included with the unit, they can be ordered separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThe FMC-1800 unit supports management by console(USB), web or SNMP.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFMC-1800 is an 18-channel SFP managed patching hub that converts Ethernet copper 100\/1000Mbps to SFPs working at 100Mbps and 1000Mbps. FMC-1800 can connect to any RJ-45 Ethernet switch and supports any third-party standard SFP module from any SFP vendor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFMC-1800 can also be used as an Ethernet copper-to-fiber media converter. With different kinds of fiber optic media, both multi-mode and single mode fiber are available as well as BiDi which allows bi-directional transmissions using only a single fiber to extend the distance of Fast Ethernet and Gigabit Ethernet networks.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe FMC-1800-AD is a great solution for managed high density Gigabit media converters in just 1RU of rack space.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1U” Height 19” 18 channels SFP patching hub\u003c\/li\u003e\n\u003cli\u003e18-port 100\/1000Base-T(X) to 18-port 100\/1000Base-X SFP\u003c\/li\u003e\n\u003cli\u003eAuto MDI\/MDIX in TP port\u003c\/li\u003e\n\u003cli\u003eAuto-Negotiation in TX port\u003c\/li\u003e\n\u003cli\u003eSupports hot-swappable SFPs working at 100 Mbps and 1000 Mbps\u003c\/li\u003e\n\u003cli\u003eSupports Web, Telnet, SNMP Management and USB-C console\u003c\/li\u003e\n\u003cli\u003eLocal configuration via USB-C port\u003c\/li\u003e\n\u003cli\u003eIngress \/ Egress bandwidth control\u003c\/li\u003e\n\u003cli\u003eSupports Link Pass-Through\u003c\/li\u003e\n\u003cli\u003eSupports Link loss Alarm\u003c\/li\u003e\n\u003cli\u003eSupports any third-party standard SFP module\u003c\/li\u003e\n\u003cli\u003eSupports SFP DDMI\u003c\/li\u003e\n\u003cli\u003eSupports Jumbo Frame packets up to 16K siize\u003c\/li\u003e\n\u003cli\u003eLayer 2 wire-speed conversion with fully transparent function\u003c\/li\u003e\n\u003cli\u003eAvailable with redundant power built-in AC(90-240V) and DC (36-72V)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eOptical Interface Connector: SFP LC\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eNumber of ports: 18\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eData rate: 100\/1000Mbps\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eDuplex mode: Full duplex\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eFiber: transparent to SFP style - MM 50\/125um, 6.25\/125um, SM 9\/125um\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eDistance: depending on SFP model - MM 2km, SM 15\/30\/50\/80\/120km, WDM 20\/40\/60\/80km\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eWavelength: depending on SFP model - 1310nm, 1550nm, CWDM 1471nm ~ 1611nm\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eElectrical Interface Connector: RJ45\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eNumber of ports: 18, data rate 10\/100\/1000Mbps, duplex mode: Half \/ Full duplex\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003eCable 10Base-T Cat. 3, 4, 5 UTP\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 40px;\"\u003e100\/1000Base-T(X) Cat.5, 5e or higher\u003cbr\u003eManagement: Console, Web, Telnet, SNMP\u003cbr\u003eControl Port: USB-C female\u003cbr\u003eStandards IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x\u003cbr\u003eLED Indications: Power FX-Link, Duplex, TX-Link\/Act, TX-Speed\u003cbr\u003ePower: 100 ~ 240VAC, 18 ~ 72 VDC\u003cbr\u003ePower Consumption AC: 105 VA DC: 70 W\u003cbr\u003eDimensions: 180 x 440 x 44mm (D x W x H)\u003cbr\u003eWeight: 3kg (6.5lbs)\u003cbr\u003eTemperature 0 ~ 60°C (Operating), -10 ~ 70°C (Storage)\u003cbr\u003eCertification CE, FCC, LVD, RoHS\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eAdditional information on FMC-1800-AD Gigabit SFP patching hub:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PDF\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" alt=\"\" width=\"16\" height=\"16\" border=\"0\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/FMC-1800-datasheet_10cfb11a-1281-4676-a57c-8607e4185aab.pdf?v=1742444830\" target=\"_blank\"\u003ePDF datasheet\u003c\/a\u003e\u003cspan\u003e; \u003c\/span\u003e\u003cimg title=\"PDF\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" alt=\"\" width=\"16\" height=\"16\" border=\"0\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/FMC-1800-manual_1f67955f-f0df-4c86-b581-5214a86d5c2d.pdf?v=1742444831\" target=\"_blank\"\u003ePDF Installation Manual\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":40737558429794,"sku":"FMC-1800-AD","price":1385.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/FMC-1800_cover_photo__01746.jpg?v=1707156401"},{"product_id":"fmc-ch17-dd-17-slot-fiber-chassis-with-dual-redundant-dc48-power-and-fans","title":"FMC-CH17-DD - 17 slot fiber chassis with dual redundant DC48 power and fans","description":"\u003cp\u003e\u003cspan\u003eFMC-CH17 series is one of the newest and most cost effective fiber aggregation solution. The FMC-CH17-DD is identical to FMC-CH17-AA and FMC-CH17-AC but provides dual redundant DC48 power supplies.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe chassis has only 2U and can accommodate 17 units of FMC series media converters. The 17 slot chassis is designed to fit a 19\" wide telco rack system, placing up to 17 fiber media converters or VDSL2 modems on just 2U space height.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eStructure of FMC chassis is simple and straightforward. There are two DC48V switching power supplies with 36V-72V input and redundancy function. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eT\u003c\/span\u003e\u003cspan\u003ehere are no centralized management features, however, the FMC series of media converters support many features like \u003c\/span\u003e\u003cstrong\u003eFEF\u003c\/strong\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cstrong\u003eFar-End-Fault\u003c\/strong\u003e\u003cspan\u003e) signaling and \u003c\/span\u003e\u003cstrong\u003eLFP\u003c\/strong\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cstrong\u003eLink-Fault-Pass\u003c\/strong\u003e\u003cspan\u003e through) function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMedia converters are switching type, store-and-forward mechanism, and are able to work Half\/Full Duplex mode.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe FMC-CH17-DD is a perfect choice for small aggregation nodes in a fiber network environment. Up to 17 fiber media converters can be put together in a chassis and benefit of redundant power supplies, saving precious space in the data networking design.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAdditional information on FMC-CH17-DD chassis:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PDF\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" alt=\"\" width=\"16\" height=\"16\" border=\"0\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/fmc-ch17-datasheet.pdf?v=1742444083\" target=\"_blank\"\u003ePDF Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"PDF\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" alt=\"\" width=\"16\" height=\"16\" border=\"0\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/fmc-ch17-manual.pdf?v=1742444083\" target=\"_blank\"\u003ePDF Installation Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":41821445914722,"sku":"FMC-CH17-DD","price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/FMCCH172__33143.jpg?v=1742444317"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/collections\/LFC-CH12_main__80444.jpg?v=1742443686","url":"https:\/\/www.fiberoptics4sale.com\/collections\/fmc-un-managed-series-fiber-chassis.oembed","provider":"Fosco Connect","version":"1.0","type":"link"}