{"title":"Optical Protection Switches","description":"\u003cp\u003eOptical Protection Systems provide automatic fiber circuit switching on alternate back-up routes when main fiber fails. Such systems are independent of protocol and wavelength, working on CWDM or DWDM systems at any speed and\/or channel.\u003c\/p\u003e\n\u003cp\u003eThe Optical Line Protection Systems (OLPS) are vital components for critical fiber optic applications. They provide automatic fiber path switching to an alternate fiber route when main fiber connection has been disabled. The OLPS systems we provide are 1:1 which means their insertion loss attenuation is minimal to the circuit.\u003c\/p\u003e\n\u003cp\u003eAll our OLPS are 19\" rack mountable, with redundant and removable power supplies and network management modules for remote monitoring and reporting. The 1:1 protection system is based on two switching modules for both Tx and Rx paths against the 1+1 protection which only has one switching module but more than double insertion loss.\u003c\/p\u003e\n\u003cp\u003eOLPS are independent of the fiber optic wavelengths or speed, making them suitable for any kind of applications like: high density CWDM and DWDM aggregation, SONET, SDH, Ethernet or Fiber Channel transport.\u003c\/p\u003e","products":[{"product_id":"olps-4rm-dd-optical-line-protection-system-8-slot-chassis-with-dual-power-and-network-management-options-rack-19-4ru","title":"OLPS-4RM-DD  Optical Line Protection System 8 slot chassis with dual power and network management options, rack 19\", 4RU","description":"\u003cp\u003e\u003cb\u003e\u003cspan\u003eNote: \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cspan\u003e\u003ci\u003ehe OLPS-4RM-DD chassis includes two OLPS-4RM-DC48 power supplies with DC 36-72V input. \u003c\/i\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cem\u003e\u003cspan\u003e\u003cspan\u003eOLPS-35 protection cards are NOT included with the OLPS-4RM-DD\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e chassis.\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan\u003e\u003cem\u003e\u003cspan\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/em\u003e\u003cbr\u003eProduct description\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe OLPS-4RM-DD is a high performance high density Optical Line Protection System for critical fiber optic transmission circuits. The chassis can hold up to 8 independent OLPS-35 1:1 optical protection cards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe chassis occupies 4RU of rack space offering double the density of the standalone OLPS-RM-35-AD system while bringing the cost per OLPS 1:1 protection system at the best value.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe management system available on the 8 slot chassis allows management of all the \u003c\/span\u003eOLPS-35\u003cspan\u003e cards with a single IP address. The 1:1 protection system has the advantage of a very low insertion loss compared with 1+1 protection systems. The \u003c\/span\u003eOLPS-35\u003cspan\u003e cards offers only 1.2dB of insertion loss, making them a favored protection choice for tight optical budget applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe OLPS is an automatic system that switches fiber communication from a main fiber line to an alternate backup fiber when the main line communication is disabled. This is done by constantly monitoring the optical level of the main line.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen signal level gets under a set threshold, communication is diverted on the secondary path in less than 35 miliseconds. Unit has management available via console and SNMP.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManagement allows set-up of threshold optical level for switching and behavior for recovery: automatic reverting to main when signal is restored, manual revert or no switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe new OLPS-4RM chassis offers 19\" rack mounting brackets with only 4RU of space used, saving vital rack space when necessary. The 8 slot OLPS rack can be loaded with OLPS-35 1:1 protection cards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe OLPS chassis provides redundant power supply system with \"hot swap\" feature, to provide continuous operation. It can accomodate both AC (110V) and DC (48V) power supply units, either in mixed or same type of power input.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"3\" cellpadding=\"1\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd width=\"180\"\u003e\u003cb\u003eChassis:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4RU height, 19\" wide mounting system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOptical Protection System:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8 slots for OLPS-35 1:1 protection cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cb\u003eOperating wavelengths:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm (+\/-50nm) and 1550nm (+\/-50nm) (on OLPS-35)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMonitored power range:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-50~+23dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy level:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInsertion Loss:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTx\u0026lt;1.2dB, Rx\u0026lt;1.2dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cb\u003eSwitching time:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;35ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePDL:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.05dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cb\u003eWDL:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.1dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDimensions(WxDxH):\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e440mm x 140mm x 356mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cb\u003eTemperature:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10~60°C (Operating); -20~75°C (Storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003edual -36 to -72V DC hot swappable power supply units, 2 slots available on chassis (optional AC 90-240V PS available on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cb\u003eMTBF:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eAdditional information on OLPS-4RM-DD unit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cimg title=\"PDF\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" alt=\"\" width=\"16\" height=\"16\" align=\"\" border=\"0\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/olps-4rm-datasheet.pdf?v=1743002831\" target=\"_blank\"\u003ePDF datasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":31932876554338,"sku":"OLPS-4RM-DD","price":1488.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/OLPS-4RM-DD.jpg?v=1599874129"},{"product_id":"frm220-ops51-optical-1-1-protection-card-for-cwdm-dwdm-systems-lc-upc-connectors-managed","title":"FRM220-OPS51 - Optical 1:1 protection card for CWDM\/DWDM systems, LC\/UPC connectors, managed","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNote: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePrice is per unit, although photo depicts two Optical Protection units.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFRM220-CH01M-AC casing is included, allowing the protection card to be managed\/configured through local RS-232 console, without the FRM220-NMC management card\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FRM220-OPS51 Optical Line Protection (OLP) unit is able to provide fiber path redundancy on a channel by channel basis. These units are particularly well suited for protection in any type of fiber data transmission, being independent from the optical protocol. The Protection card will work with any DWDM\/CWDM system or regular 1310\/1550nm grey fiber, covering SONET. SDH, Ethernet, Fibre Channel or any other optical protocols.\u003c\/p\u003e\n\u003cp\u003eThis solution includes monitoring capabilities for both the working and protected path fibers. In case of a fiber cut in the active path, traffic will be switched over to the protected path in less than 50 ms.\u003c\/p\u003e\n\u003cp\u003eMonitoring is available through SNMP Management when FRM220-OPS51 card is placed in FRM220 rack with SNMP management. The management can view the converter card's status, type, version, fiber link status and alarms. The card can be configured to enable or disable the port, reset the port, and configure receive threshold levels for path switching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1:1 full optical protection (least insertion loss solution)\u003c\/li\u003e\n\u003cli\u003eLow channel cross talk \u0026lt; -55dB\u003c\/li\u003e\n\u003cli\u003eLow insertion loss \u0026lt; 2.5dB\u003c\/li\u003e\n\u003cli\u003eLatch feature, if power is lost the switch remains in its current state\u003c\/li\u003e\n\u003cli\u003eProtection transition \u0026lt; 50 ms\u003c\/li\u003e\n\u003cli\u003eWorks with any combination of 1 ~16 wavelengths\u003c\/li\u003e\n\u003cli\u003eTraffic is switched in one of three modes : revertive,non-revertive, manual\u003c\/li\u003e\n\u003cli\u003eProgrammable Rx threshold setting for switch-over\u003c\/li\u003e\n\u003cli\u003eOptical Interface Type : LC connectors\u003c\/li\u003e\n\u003cli\u003eWorking and protected lines are physically separated fiber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eAdditional information on FRM220-OPS51 OLPS unit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cimg border=\"0\" align=\"middle\" height=\"16\" width=\"16\" alt=\"\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" title=\"PDF\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/FRM220-OPS51_52-datasheet.pdf?v=1743001460\" rel=\"noopener\" target=\"_blank\"\u003ePDF Datasheet\u003c\/a\u003e. \u003c\/p\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":41834406346850,"sku":"FRM220-OPS51","price":1559.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/SML-Protection__90830.jpg?v=1743001499"},{"product_id":"olps-rm-35-ad-optical-line-protection-system-1-1-with-dual-power-and-network-management-options-rack-19-1u","title":"OLPS-RM-35-AD - Optical Line Protection System 1:1 with dual power and network management options, rack 19\", 1U","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eThe OLPS-RM-35-AD includes one OLPS-RM-AC power supply with AC90-240V input and one OLPS-RM-DC48 power supply with DC 36-72V input.\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OLPS-RM-35-AD is a high performance Optical Line Protection System for critical fiber optic transmission circuits. The OLPS works as a 1:1 protection system. The 1:1 protection system has the advantage of a very low insertion loss compared with 1+1 protection systems. The OLPS-RM-35-AD offers only 1.2dB of insertion loss, making it a favored protection choice for tight optical budget applications.\u003c\/p\u003e\n\u003cp\u003eThe OLPS is an automatic system that switches fiber communication from a main fiber line to an alternate backup fiber when the main line communication is disabled. This is done by constantly monitoring the optical level of the main line.\u003c\/p\u003e\n\u003cp\u003eWhen signal level gets under a set threshold, communication is diverted on the secondary path in less than 35 miliseconds. Unit has management available via console and SNMP.\u003c\/p\u003e\n\u003cp\u003eManagement allows set-up of threshold optical level for switching and behavior for recovery: automatic reverting to main when signal is restored, manual revert or no switch.\u003c\/p\u003e\n\u003cp\u003eThe new OLPS-RM-35-AD chassis offers 19\" rack mounting brackets with only 1U of space used, saving vital rack space when necessary. An 8 slot OLPS rack on 4RU space is available for double rack space density, the OLPS-4RM-DD chassis\u003c\/p\u003e\n\u003cp\u003eThe OLPS chassis provides redundant power supply system with \"hot swap\" feature, to provide continuous operation. It can accomodate both AC (110V) and DC (48V) power supply units, either in mixed or same type of power input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"1\" cellspacing=\"3\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd width=\"180\"\u003e\u003cstrong\u003eChassis:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1RU height, 19\"  wide mounting system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Protection System:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating wavelengths:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm (+\/-50nm) and 1550nm (+\/-50nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored power range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50~+23dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy level:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsertion Loss:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTx\u0026lt;1.2dB, Rx\u0026lt;1.2dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching time:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;35ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.05dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWDL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.1dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions(WxDxH):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440mm x 140mm x 89mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10~60°C (Operating); -20~75°C (Storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90-260V AC or -36 to -72V DC hot swappable power supply units, 2 slots available on chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAdditional information on OLPS-RM-35-AD unit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cimg border=\"0\" align=\"\" height=\"16\" width=\"16\" alt=\"\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" title=\"PDF\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/olps-rm-35-datasheet.pdf?v=1743002543\" target=\"_blank\"\u003ePDF datasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":41834457006178,"sku":"OLPS-RM-35-AD","price":2645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/OLPS-35-RM-AD__07622.jpg?v=1743002620"},{"product_id":"olps-35-optical-line-protection-system-1-1-card-for-olps-4rm-8-slot-chassis","title":"OLPS-35 - Optical Line Protection System 1:1 card for OLPS-4RM 8 slot chassis","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eUp to 8 OLPS-35 cards can be installed in a single OLPS-4RM 19\" 4RU chassis.\u003c\/em\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OLPS-35 is a high performance Optical Line Protection System for critical fiber optic transmission circuits. The OLPS works as a 1:1 duplex path protection system. OLPS-35 is only a card and must be inserted in the 8 slot OLPS-4RM chassis to be utilized effectively.\u003c\/p\u003e\n\u003cp\u003eThe 1:1 protection system has the advantage of a very low insertion loss compared with 1+1 protection systems. The OLPS-35 offers only 1.2dB of insertion loss, making it a favored protection choice for tight optical budget applications.\u003c\/p\u003e\n\u003cp\u003eThe OLPS is an automatic system that switches fiber communication from a main fiber line to an alternate backup fiber when the main line communication is disabled. This is done by constantly monitoring the optical level of the main line. When signal level gets under a set threshold, communication is diverted on the secondary path in less than 35 miliseconds.\u003c\/p\u003e\n\u003cp\u003eUnit has management available via console and SNMP. Management allows set-up of threshold optical level for switching and behavior for recovery: automatic reverting to main when signal is restored, manual revert or no switch. The new OLPS-35 card together with the\u003cspan\u003e \u003c\/span\u003eOLPS-4RM\u003cspan\u003e \u003c\/span\u003echassis offers 19\" rack mounting brackets with high density, suitable for high density data center applications.\u003c\/p\u003e\n\u003cp\u003eBoth OLPS chassis (1RU and 4RU) have redundant power supply system with \"hot swap\" feature, to provide continuous operation. They can accomodate both AC (110V) and DC (48V) power supply units, either in mixed or same type of power input.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eTechnical specifications OLPS-35 card and OLPS-4RM chassis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellspacing=\"3\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd width=\"180\"\u003e\u003cstrong\u003eChassis:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4RU height, 19\"  wide mounting system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Protection System:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating wavelengths:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310nm (+\/-50nm) and 1550nm (+\/-50nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored power range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50~+23dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy level:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsertion Loss:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTx\u0026lt;1.2dB, Rx\u0026lt;1.2dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching time:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;35ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.05dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWDL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.1dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions(WxDxH):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440mm x 140mm x 356mm (4RU chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10~60°C (Operating); -20~75°C (Storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90-260V AC or -36 to -72V DC hot swappable power supply units, 2 slots available on chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#dbebfc\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAdditional information on OLPS-4RM chassis and OLPS-35 card units:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cimg title=\"PDF\" src=\"https:\/\/cdn11.bigcommerce.com\/s-ud26lew7xv\/product_images\/uploaded_images\/pdf.png\" alt=\"\" width=\"16\" height=\"16\" align=\"\" border=\"0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/olps-4rm-datasheet.pdf?v=1743002831\" target=\"_blank\" rel=\"noopener\"\u003ePDF datasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"CTC Union","offers":[{"title":"Default Title","offer_id":41834465558626,"sku":"OLPS-35","price":1595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/OLPS-35__81063.jpg?v=1743003033"}],"url":"https:\/\/www.fiberoptics4sale.com\/collections\/optical-protection-switchs.oembed","provider":"Fosco Connect","version":"1.0","type":"link"}