{"title":"Optical Spectrum Analyzers","description":null,"products":[{"product_id":"osx-80c","title":"C-Band Optical Spectrum Analyzer","description":"\u003cp\u003e\u003cstrong\u003eC-Band Optical Spectrum Analyzer\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e The  Hand Held Optical Spectrum Analyzers offer full featured analysis of DWDM and CWDM systems in a truly portable package. Available in WDM PON and ROADM units with a CWDM Channel Analyzer. This OSA has a super fast acquisition time of \u0026lt;1s per scan , and Pass\/Fail feature with an easy to read color display. The OSA will store up to 1000 tests and is shipped with Windows compatible software for fast and easy reporting. \u003c\/p\u003e\n\n\u003cul\u003e\n\n  \u003cli\u003eEasy Operation with Help Mode\u003c\/li\u003e\n\n  \u003cli\u003e50 or 100 GHz DWDM Channel Spacing\u003c\/li\u003e\n\n  \u003cli\u003eFast with Less Than One Second Scan\u003c\/li\u003e\n\n  \u003cli\u003eOver 80 Challens on the ITU Grid\u003c\/li\u003e\n\n  \u003cli\u003eReal Time Mode\u003c\/li\u003e\n\n  \u003cli\u003ePass\/Fail Thresholds\u003c\/li\u003e\n\n  \u003cli\u003eSpectrum, Bar Graph \u0026amp; Table Displays\u003c\/li\u003e\n\n  \u003cli\u003e4\" Color Display\u003c\/li\u003e\n\n  \u003cli\u003eRugged Case w\/ Impact Resistant Boot\u003c\/li\u003e\n\n  \u003cli\u003e8hr Battery Life\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eDownload Product Spec Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n  \u003cli\u003e\u003ca href=\"https:\/\/s3-us-west-1.amazonaws.com\/foscoshopify\/pdf\/Hand-Held-Optical-Spectrum-Analyzer.pdf\"\u003eHand Held Optical Spectrum Analyzer(pdf)\u003c\/a\u003e\u003c\/li\u003e\n\n\u003c\/ul\u003e","brand":"Mooseline","offers":[{"title":"Default Title","offer_id":31932937502818,"sku":"OSX-80C","price":6495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/Hand-Held-Optical-Spectrum-Analyzer.jpeg?v=1599875300"},{"product_id":"osx-80l","title":"L-Band Optical Spectrum Analyzer","description":"\u003cp\u003e\u003cstrong\u003eL-Band Optical Spectrum Analyzer\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e The  Hand Held Optical Spectrum Analyzers offer full featured analysis of DWDM and CWDM systems in a truly portable package. Available in WDM PON and ROADM units with a CWDM Channel Analyzer. This OSA has a super fast acquisition time of \u0026lt;1s per scan , and Pass\/Fail feature with an easy to read color display. The OSA will store up to 1000 tests and is shipped with Windows compatible software for fast and easy reporting. \u003c\/p\u003e\n\n\u003cul\u003e\n\n  \u003cli\u003eEasy Operation with Help Mode\u003c\/li\u003e\n\n  \u003cli\u003e50 or 100 GHz DWDM Channel Spacing\u003c\/li\u003e\n\n  \u003cli\u003eFast with Less Than One Second Scan\u003c\/li\u003e\n\n  \u003cli\u003eOver 80 Challens on the ITU Grid\u003c\/li\u003e\n\n  \u003cli\u003eReal Time Mode\u003c\/li\u003e\n\n  \u003cli\u003ePass\/Fail Thresholds\u003c\/li\u003e\n\n  \u003cli\u003eSpectrum, Bar Graph \u0026amp; Table Displays\u003c\/li\u003e\n\n  \u003cli\u003e4\" Color Display\u003c\/li\u003e\n\n  \u003cli\u003eRugged Case w\/ Impact Resistant Boot\u003c\/li\u003e\n\n  \u003cli\u003e8hr Battery Life\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eDownload Product Spec Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n  \u003cli\u003e\u003ca href=\"https:\/\/s3-us-west-1.amazonaws.com\/foscoshopify\/pdf\/Hand-Held-Optical-Spectrum-Analyzer.pdf\"\u003eHand Held Optical Spectrum Analyzer(pdf)\u003c\/a\u003e\u003c\/li\u003e\n\n\u003c\/ul\u003e","brand":"Mooseline","offers":[{"title":"Default Title","offer_id":31932937404514,"sku":"OSX-80L","price":6495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/Hand-Held-Optical-Spectrum-Analyzer_ea15b4c4-adf8-4b7b-957a-33aebe23deb9.jpeg?v=1599875299"},{"product_id":"th-osa201c-fourier-transform-optical-spectrum-analyzer-350-1100-nm","title":"TH-OSA201C - Fourier Transform Optical Spectrum Analyzer, 350 - 1100 nm","description":"\u003cp\u003eTH-OSA201C - Fourier Transform Optical Spectrum Analyzer, 350 - 1100 nm\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/STN050453-E0W.pdf?v=1672856197\"\u003eProduct Drawing\u003c\/a\u003e\u003c\/p\u003e\n\u003cul class=\"SGBullet\"\u003e\n\u003cli\u003eFive Models Optimized for Different Spectral Ranges\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eTHOSA201C: 350 - 1100 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA202C: 600 - 1700 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA203C: 1.0 - 2.6 µm (10 000 - 3846 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA205C: 1.0 - 5.6 µm (10 000 - 1786 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA207C: 1.0 - 12.0 µm (10 000 - 833 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo Optical Input Ports\n\u003cul\u003e\n\u003cli\u003eFC\/PC Fiber-Coupled Input\u003c\/li\u003e\n\u003cli\u003eFree-Space Input with Four 4-40 Taps for 30 mm Cage System Compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-In Hose Connections for Optional Purging\u003c\/li\u003e\n\u003cli\u003eIncludes Windows\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLaptop and Items Shown in\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eShipping List\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTab\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEach THOSA20xC instrument includes a Windows\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e laptop with our OSA software suite version 3.20 pre-installed and a USB 2.0 cable. This software has a graphical user interface (GUI) that includes a variety of measurement and analysis tools; please see the \u003c\/span\u003e\u003cem\u003eSoftware\u003c\/em\u003e\u003cspan\u003e tab for a detailed overview of the software capabilities. To easily interface with the OSAs, an extensive set of drivers are also available for LabVIEW\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e, C, C++, and C#. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHose Inlets for Optional Purging\u003c\/strong\u003e\u003cbr\u003eTo reduce the presence of water absorption lines in the measured spectrum, our OSAs offer two 1\/4\" inner diameter quick-connect hose connections on the back panel, through which the interferometer can be purged with dry air. Pure Air Circulator Unit is ideal for this task. Purging the OSA is not generally necessary, since none of the optics are made from hygroscopic materials, but can be useful for applications such as gas detection and identification where the presence of trace gases in the housing may affect the measurement. An example setup that uses the THOSA203C instrument is described in the \u003cem\u003eGas Spectroscopy\u003c\/em\u003e tab.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fosco Connect","offers":[{"title":"Default Title","offer_id":40215045242978,"sku":"THOSA201C","price":45925.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/STN050453-xl.jpg?v=1672856110"},{"product_id":"th-osa202c-fourier-transform-optical-spectrum-analyzer-600-1700-nm","title":"TH-OSA202C - Fourier Transform Optical Spectrum Analyzer, 600 - 1700 nm","description":"\u003cp\u003eTH-OSA202C - Fourier Transform Optical Spectrum Analyzer, 600 - 1700 nm\u003c\/p\u003e\n\u003cul class=\"SGBullet\"\u003e\n\u003cli\u003eFive Models Optimized for Different Spectral Ranges\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eTHOSA201C: 350 - 1100 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA202C: 600 - 1700 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA203C: 1.0 - 2.6 µm (10 000 - 3846 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA205C: 1.0 - 5.6 µm (10 000 - 1786 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA207C: 1.0 - 12.0 µm (10 000 - 833 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo Optical Input Ports\n\u003cul\u003e\n\u003cli\u003eFC\/PC Fiber-Coupled Input\u003c\/li\u003e\n\u003cli\u003eFree-Space Input with Four 4-40 Taps for 30 mm Cage System Compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-In Hose Connections for Optional Purging\u003c\/li\u003e\n\u003cli\u003eIncludes Windows\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLaptop and Items Shown in\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eShipping List\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTab\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEach THOSA20xC instrument includes a Windows\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e laptop with our OSA software suite version 3.20 pre-installed and a USB 2.0 cable. This software has a graphical user interface (GUI) that includes a variety of measurement and analysis tools; please see the \u003c\/span\u003e\u003cem\u003eSoftware\u003c\/em\u003e\u003cspan\u003e tab for a detailed overview of the software capabilities. To easily interface with the OSAs, an extensive set of drivers are also available for LabVIEW\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e, C, C++, and C#. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHose Inlets for Optional Purging\u003c\/strong\u003e\u003cbr\u003eTo reduce the presence of water absorption lines in the measured spectrum, our OSAs offer two 1\/4\" inner diameter quick-connect hose connections on the back panel, through which the interferometer can be purged with dry air. Pure Air Circulator Unit is ideal for this task. Purging the OSA is not generally necessary, since none of the optics are made from hygroscopic materials, but can be useful for applications such as gas detection and identification where the presence of trace gases in the housing may affect the measurement. An example setup that uses the THOSA203C instrument is described in the \u003cem\u003eGas Spectroscopy\u003c\/em\u003e tab.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/STN050454-E0W.pdf?v=1672860376\"\u003e\u003cstrong\u003eProduct Drawing\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Fosco Connect","offers":[{"title":"Default Title","offer_id":40215125786722,"sku":"THOSA202C","price":42925.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/STN050453-xl_0de7352f-6e33-448b-8fc3-9ce556cd8eab.jpg?v=1672859999"},{"product_id":"th-osa203c-fourier-transform-optical-spectrum-analyzer-1-0-2-6-m","title":"TH-OSA203C - Fourier Transform Optical Spectrum Analyzer, 1.0 - 2.6 µm","description":"\u003cp\u003eTH-OSA203C - Fourier Transform Optical Spectrum Analyzer, 1.0 - 2.6 µm\u003c\/p\u003e\n\u003cul class=\"SGBullet\"\u003e\n\u003cli\u003eFive Models Optimized for Different Spectral Ranges\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eTHOSA201C: 350 - 1100 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA202C: 600 - 1700 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA203C: 1.0 - 2.6 µm (10 000 - 3846 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA205C: 1.0 - 5.6 µm (10 000 - 1786 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA207C: 1.0 - 12.0 µm (10 000 - 833 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo Optical Input Ports\n\u003cul\u003e\n\u003cli\u003eFC\/PC Fiber-Coupled Input\u003c\/li\u003e\n\u003cli\u003eFree-Space Input with Four 4-40 Taps for 30 mm Cage System Compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-In Hose Connections for Optional Purging\u003c\/li\u003e\n\u003cli\u003eIncludes Windows\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLaptop and Items Shown in\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eShipping List\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTab\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEach THOSA20xC instrument includes a Windows\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e laptop with our OSA software suite version 3.20 pre-installed and a USB 2.0 cable. This software has a graphical user interface (GUI) that includes a variety of measurement and analysis tools; please see the \u003c\/span\u003e\u003cem\u003eSoftware\u003c\/em\u003e\u003cspan\u003e tab for a detailed overview of the software capabilities. To easily interface with the OSAs, an extensive set of drivers are also available for LabVIEW\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e, C, C++, and C#. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHose Inlets for Optional Purging\u003c\/strong\u003e\u003cbr\u003eTo reduce the presence of water absorption lines in the measured spectrum, our OSAs offer two 1\/4\" inner diameter quick-connect hose connections on the back panel, through which the interferometer can be purged with dry air. Pure Air Circulator Unit is ideal for this task. Purging the OSA is not generally necessary, since none of the optics are made from hygroscopic materials, but can be useful for applications such as gas detection and identification where the presence of trace gases in the housing may affect the measurement. An example setup that uses the THOSA203C instrument is described in the \u003cem\u003eGas Spectroscopy\u003c\/em\u003e tab.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/STN050561-E0W.pdf?v=1672860972\"\u003e\u003cstrong\u003eProduct Drawing\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Fosco Connect","offers":[{"title":"Default Title","offer_id":40215140565090,"sku":"THOSA203C","price":36525.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/STN050453-xl_3928860c-94f5-4456-a31c-75e19e7ace4c.jpg?v=1672860873"},{"product_id":"th-osa205c-fourier-transform-optical-spectrum-analyzer-1-0-5-6-m","title":"TH-OSA205C - Fourier Transform Optical Spectrum Analyzer, 1.0 - 5.6 µm","description":"\u003cp\u003eTH-OSA205C - Fourier Transform Optical Spectrum Analyzer, 1.0 - 5.6 µm\u003c\/p\u003e\n\u003cul class=\"SGBullet\"\u003e\n\u003cli\u003eFive Models Optimized for Different Spectral Ranges\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eTHOSA201C: 350 - 1100 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA202C: 600 - 1700 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA203C: 1.0 - 2.6 µm (10 000 - 3846 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA205C: 1.0 - 5.6 µm (10 000 - 1786 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA207C: 1.0 - 12.0 µm (10 000 - 833 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo Optical Input Ports\n\u003cul\u003e\n\u003cli\u003eFC\/PC Fiber-Coupled Input\u003c\/li\u003e\n\u003cli\u003eFree-Space Input with Four 4-40 Taps for 30 mm Cage System Compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-In Hose Connections for Optional Purging\u003c\/li\u003e\n\u003cli\u003eIncludes Windows\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLaptop and Items Shown in\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eShipping List\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTab\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEach THOSA20xC instrument includes a Windows\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e laptop with our OSA software suite version 3.20 pre-installed and a USB 2.0 cable. This software has a graphical user interface (GUI) that includes a variety of measurement and analysis tools; please see the \u003c\/span\u003e\u003cem\u003eSoftware\u003c\/em\u003e\u003cspan\u003e tab for a detailed overview of the software capabilities. To easily interface with the OSAs, an extensive set of drivers are also available for LabVIEW\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e, C, C++, and C#. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHose Inlets for Optional Purging\u003c\/strong\u003e\u003cbr\u003eTo reduce the presence of water absorption lines in the measured spectrum, our OSAs offer two 1\/4\" inner diameter quick-connect hose connections on the back panel, through which the interferometer can be purged with dry air. Pure Air Circulator Unit is ideal for this task. Purging the OSA is not generally necessary, since none of the optics are made from hygroscopic materials, but can be useful for applications such as gas detection and identification where the presence of trace gases in the housing may affect the measurement. An example setup that uses the THOSA203C instrument is described in the \u003cem\u003eGas Spectroscopy\u003c\/em\u003e tab.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/STN050562-E0W.pdf?v=1672861320\"\u003e\u003cstrong\u003eProduct Drawing\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Fosco Connect","offers":[{"title":"Default Title","offer_id":40215143022690,"sku":"THOSA205C","price":38558.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/STN050453-xl_32fc885a-af9d-48b4-8eb8-cdd9dc95d161.jpg?v=1672861235"},{"product_id":"th-osa207c-fourier-transform-optical-spectrum-analyzer-1-0-12-0-m","title":"TH-OSA207C - Fourier Transform Optical Spectrum Analyzer, 1.0 - 12.0 µm","description":"\u003cp\u003eTH-OSA207C - Fourier Transform Optical Spectrum Analyzer, 1.0 - 12.0 µm\u003c\/p\u003e\n\u003cul class=\"SGBullet\"\u003e\n\u003cli\u003eFive Models Optimized for Different Spectral Ranges\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eTHOSA201C: 350 - 1100 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA202C: 600 - 1700 nm\u003c\/li\u003e\n\u003cli\u003eTHOSA203C: 1.0 - 2.6 µm (10 000 - 3846 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA205C: 1.0 - 5.6 µm (10 000 - 1786 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eTHOSA207C: 1.0 - 12.0 µm (10 000 - 833 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo Optical Input Ports\n\u003cul\u003e\n\u003cli\u003eFC\/PC Fiber-Coupled Input\u003c\/li\u003e\n\u003cli\u003eFree-Space Input with Four 4-40 Taps for 30 mm Cage System Compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-In Hose Connections for Optional Purging\u003c\/li\u003e\n\u003cli\u003eIncludes Windows\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLaptop and Items Shown in\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eShipping List\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTab\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEach THOSA20xC instrument includes a Windows\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e laptop with our OSA software suite version 3.20 pre-installed and a USB 2.0 cable. This software has a graphical user interface (GUI) that includes a variety of measurement and analysis tools; please see the \u003c\/span\u003e\u003cem\u003eSoftware\u003c\/em\u003e\u003cspan\u003e tab for a detailed overview of the software capabilities. To easily interface with the OSAs, an extensive set of drivers are also available for LabVIEW\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e, C, C++, and C#. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHose Inlets for Optional Purging\u003c\/strong\u003e\u003cbr\u003eTo reduce the presence of water absorption lines in the measured spectrum, our OSAs offer two 1\/4\" inner diameter quick-connect hose connections on the back panel, through which the interferometer can be purged with dry air. Pure Air Circulator Unit is ideal for this task. Purging the OSA is not generally necessary, since none of the optics are made from hygroscopic materials, but can be useful for applications such as gas detection and identification where the presence of trace gases in the housing may affect the measurement. An example setup that uses the THOSA203C instrument is described in the \u003cem\u003eGas Spectroscopy\u003c\/em\u003e tab.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/STN050563-E0W.pdf?v=1672861648\"\u003e\u003cstrong\u003eProduct Drawing\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Fosco Connect","offers":[{"title":"Default Title","offer_id":40215144071266,"sku":"TH-OSA207C","price":48520.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/STN050453-xl_d6393ffa-0039-4e11-b231-a4f0f68a00b1.jpg?v=1672861547"},{"product_id":"th-osa305-redstone-fourier-transform-optical-spectrum-analyzer-1-9-ghz-resolution-1-0-5-6-m","title":"TH-OSA305 - Redstone Fourier Transform Optical Spectrum Analyzer, 1.9 GHz Resolution, 1.0 - 5.6 µm","description":"\u003cp\u003eTH-OSA305 - Redstone Fourier Transform Optical Spectrum Analyzer, 1.9 GHz Resolution, 1.0 - 5.6 µm\u003c\/p\u003e\n\u003cul class=\"SGBullet\"\u003e\n\u003cli\u003eMulti-Detector Configuration for Broad Operation Range: 1.0 - 5.6 µm (10 000 - 1786 cm\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/li\u003e\n\u003cli\u003eFour Resolution Settings and Three Sensitivity Levels \u003c\/li\u003e\n\u003cli\u003eFront Panel Access to Frequency-Locked Laser for Wavelength Calibration\u003c\/li\u003e\n\u003cli\u003eTwo Optical Input Ports\n\u003cul\u003e\n\u003cli\u003eFC\/PC Fiber-Coupled Input\u003c\/li\u003e\n\u003cli\u003eFree-Space Input with Four 4-40 Taps for 60 mm Cage System Compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrigger Input for External Synchronization\u003c\/li\u003e\n\u003cli\u003eBuilt-In Hose Connections for Optional Purging\u003c\/li\u003e\n\u003cli\u003eIncludes Windows\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLaptop and Items Shown in\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eShipping List\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTab \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eResolution and Sensitivity\u003c\/strong\u003e\u003cbr\u003eThis high-performance OSA offers four resolution settings that can resolve spectral features 4.0, 1.0, 0.25, or 0.0625 cm\u003csup\u003e-1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eapart. Three sensitivity levels are also available, which control the acquisition speed and available gain levels. For detailed specifications on the acquisition update frequency for each sensitivity and resolution setting, please see the\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eSpecs\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003etab. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration Laser\u003c\/strong\u003e\u003cbr\u003eFor the Redstone OSA, the internal frequency-locked calibration laser is accessible through the FC\/APC fiber output located above the power switch on the front panel. This can be used for wavelength calibration by connecting the front-panel output to the FC\/PC fiber input using the included single mode patch cable. During calibration, the software compares the measured wavelength to the reference and performs a calibration if necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInterferogram Averaging\u003cbr\u003e\u003c\/strong\u003eAn integrated internal broadband reference source allows the Redstone OSA to accurately determine the location of zero path difference (ZPD) between the two optical branches. The ZPD can be used to average interferograms, which reduces the signal-to-noise ratio. The beam profile overlap between the two branches is optimized using piezoelectric actuators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe Redstone OSA includes a Windows\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e laptop with our OSA software suite version 3.20 pre-installed and a high-speed USB 3.0 cable. This software has a graphical user interface (GUI) that includes a variety of measurement and analysis tools; please see the \u003c\/span\u003e\u003cem\u003eSoftware\u003c\/em\u003e\u003cspan\u003e tab for a detailed overview of the software capabilities. To easily interface with the OSAs, an extensive set of drivers are also available for LabVIEW\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e, C, C++, and C#.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/STN053070-E0W.pdf?v=1672862254\"\u003eProduct Drawing\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Fosco Connect","offers":[{"title":"Default Title","offer_id":40215146594402,"sku":"THOSA305","price":87950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/products\/STN053070-xl.jpg?v=1672861822"}],"url":"https:\/\/www.fiberoptics4sale.com\/collections\/optical-spectrum-analyzers.oembed","provider":"Fosco Connect","version":"1.0","type":"link"}