{"product_id":"6-fiber-multimode-62-5um-om1-indoor-outdoor-fiber-optic-cable-with-aluminum-interlocking-armor-aia-plenum-rated-per-meter","title":"6 Fiber Multimode 62.5um OM1 Indoor\/Outdoor Fiber Optic Cable with Aluminum Interlocking Armor (AIA) Plenum Rated (per meter)","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis 6-fiber multimode 62.5um OM1 indoor\/outdoor cable features a distribution-style construction and is plenum rated for versatile installation environments. Designed for flexibility and ease of handling, this cable utilizes water-blocking aramid yarn strength members to ensure long-term durability in varied conditions.\u003c\/p\u003e\n\u003cp\u003eThe cable is constructed with 900µm tight-buffered fibers, which allow for direct termination of connectors without the need for additional breakout kits, simplifying the installation process and reducing overall labor costs. The rugged, UV-resistant black jacket provides essential protection for both indoor and outdoor use. This specific version includes aluminum interlocking armor (AIA) to offer superior mechanical protection in high-traffic or demanding environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e900µm Tight Buffered Fibers\u003c\/strong\u003e\u003cbr\u003eFacilitates direct field termination of connectors, eliminating the need for breakout kits and reducing installation complexity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlenum Rated Jacket\u003c\/strong\u003e\u003cbr\u003eMeets stringent fire safety requirements for installation within building air-handling spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor\/Outdoor Versatility\u003c\/strong\u003e\u003cbr\u003eDual-purpose design allows for seamless transitions between indoor and outdoor network segments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater-Blocking Aramid Yarn\u003c\/strong\u003e\u003cbr\u003eProvides essential moisture protection and high tensile strength to safeguard the fiber core.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Interlocking Armor (AIA)\u003c\/strong\u003e\u003cbr\u003eAdds a layer of mechanical protection against crushing and impact in rugged use applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUV Resistant Black Jacket\u003c\/strong\u003e\u003cbr\u003eProtects the cable structure from degradation when exposed to sunlight in outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor\/outdoor campus network backbones\u003c\/li\u003e\n\u003cli\u003ePlenum-rated building risers\u003c\/li\u003e\n\u003cli\u003eDemanding environments requiring mechanical protection\u003c\/li\u003e\n\u003cli\u003eDirect conduit or innerduct installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Mode\u003c\/td\u003e\n\u003ctd\u003eMultimode (OM1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Size\u003c\/td\u003e\n\u003ctd\u003e62.5um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Type\u003c\/td\u003e\n\u003ctd\u003eAluminum Interlocking Armor (AIA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003ePlenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e14.15mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Color\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be buried directly?\u003c\/strong\u003e\u003cbr\u003eNo, when used in burial applications, this cable must be placed inside a conduit or innerduct.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable suitable for lashing?\u003c\/strong\u003e\u003cbr\u003eNo, this cable is not recommended for lashing applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable require a breakout kit?\u003c\/strong\u003e\u003cbr\u003eNo, because it uses 900µm tight-buffered fibers, connectors can be terminated directly onto the fibers without break-out kits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the jacket rated for plenum installations?\u003c\/strong\u003e\u003cbr\u003eYes, this version is rated for plenum environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the armor?\u003c\/strong\u003e\u003cbr\u003eThe aluminum interlocking armor provides enhanced protection against physical crushing and impact, making it suitable for rugged applications.\u003c\/p\u003e","brand":"Fosco Connect","offers":[{"title":"Default Title","offer_id":50676908261474,"sku":"M62IO06C3NPBLAIA","price":5.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/tlc-black-in-out_1_4.jpg?v=1792173788","url":"https:\/\/www.fiberoptics4sale.com\/products\/6-fiber-multimode-62-5um-om1-indoor-outdoor-fiber-optic-cable-with-aluminum-interlocking-armor-aia-plenum-rated-per-meter","provider":"Fosco Connect","version":"1.0","type":"link"}