{"product_id":"belden-osp-central-loose-tube-cable-12-fiber-multimode-62-5-125um-black-per-meter","title":"Belden OSP Central Loose Tube Cable 12 Fiber Multimode 62.5\/125um Black (per meter)","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Belden OSP Central Loose Tube Cable is a robust, field-proven solution designed for outdoor environments. Featuring a 12-fiber multimode 62.5\/125um (OM1) configuration, this cable is engineered for durability and reliable performance in demanding external conditions.\u003c\/p\u003e\n\u003cp\u003eThis cable utilizes a central tube construction that is fully waterblocked with gel-filled buffer tubes, ensuring protection against moisture ingress. Its design includes fiberglass strength members, providing resistance to crush, impact, and abrasion without the handling complexity of metallic rods. It is an ideal choice for campus OSP backbones, drop cable installations, and telecommunications trunking.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWaterblocking Gel\u003c\/strong\u003e\u003cbr\u003eFeatures a gel-filled buffer tube that prevents moisture migration, extending the longevity of the fiber in outdoor environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentral Tube Design\u003c\/strong\u003e\u003cbr\u003eAn economical architecture for low-fiber-count applications, allowing for quick and simple end preparation during termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Durability\u003c\/strong\u003e\u003cbr\u003eConstructed to be resistant to crush, impact, and abrasion, ensuring signal integrity in harsh environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Metallic Strength\u003c\/strong\u003e\u003cbr\u003eUtilizes fiberglass strength members, simplifying handling and providing a non-conductive solution for installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Temperature Tolerance\u003c\/strong\u003e\u003cbr\u003eDesigned to maintain performance characteristics in operating temperatures ranging from -40°C to 70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry Standard Compliance\u003c\/strong\u003e\u003cbr\u003eMeets TIA\/EIA-568.3-D and ICEA S-87-640 standards for high-quality, long-haul networking applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCampus OSP backbones\u003c\/li\u003e\n\u003cli\u003eDrop cable deployments\u003c\/li\u003e\n\u003cli\u003eTelecommunications and data trunking\u003c\/li\u003e\n\u003cli\u003eLashed aerial installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border:1px solid #ddd;padding:8px;background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border:1px solid #ddd;padding:8px;background:#f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBelden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFS1C012N0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFiber Count\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFiber Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOM1 (62.5\/125um)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8.0 mm (0.315 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eJacket Material\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003ePE (Polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eJacket Color\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTensile Strength (Installation)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2700 N (600 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTensile Strength (Operation)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e890 N (200 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e-40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eMinimum Bend Radius (Installation)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20 x OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eMinimum Bend Radius (Long Term)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e15 x OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTIA\/EIA-568.3-D, ICEA S-87-640, RoHS II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable suitable for direct burial?\u003c\/strong\u003e\u003cbr\u003eWhile this is an OSP (Outside Plant) cable with water-blocking properties, always consult local building codes and the specific installation guidelines provided in the technical data sheet for burial requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the jacket material?\u003c\/strong\u003e\u003cbr\u003eThe outer jacket is constructed from PE (Polyethylene), which provides excellent UV and moisture resistance for outdoor deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable contain metallic elements?\u003c\/strong\u003e\u003cbr\u003eNo, it uses fiberglass strength members, making it a non-metallic, dielectric cable design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this be used for indoor\/outdoor transition?\u003c\/strong\u003e\u003cbr\u003eThis cable is designed primarily for OSP applications. Verify your local fire safety codes if transitioning into a building plenum or riser space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the fiber color coding standard?\u003c\/strong\u003e\u003cbr\u003eThe fiber color coding follows the TIA\/EIA 598-B standard.\u003c\/p\u003e\n\u003ch3\u003eManufacturer Datasheet\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4160193.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload verified manufacturer PDF datasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Belden","offers":[{"title":"Default Title","offer_id":50641708974178,"sku":"FS1C012N0","price":7.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/FS1C012N0_main.jpg?v=1792014838","url":"https:\/\/www.fiberoptics4sale.com\/products\/belden-osp-central-loose-tube-cable-12-fiber-multimode-62-5-125um-black-per-meter","provider":"Fosco Connect","version":"1.0","type":"link"}