{"product_id":"franklin-1250-ltc-4-i-m-load-tap-changer-monitor-4-20ma-i-m","title":"Franklin 1250-LTC-4-I-M Load Tap Changer Monitor, 4-20mA I-M","description":"\u003ch2\u003eFranklin INCON 1250-LTC-4-I-M Programmable LTC Position Monitor\u003c\/h2\u003e\n\u003cp\u003eThe Franklin INCON® 1250-LTC-4-I-M is an advanced programmable Load Tap Changer (LTC) Position Monitor designed for precise transformer monitoring and grid reliability. It bridges the critical data gap between the LTC and its controller by relaying precise position information and tracking continuous LTC movement, which allows for active predictive maintenance.\u003c\/p\u003e\n\u003cp\u003eEngineered for utility-grade electrical infrastructure, this specific model features a 4-20 mA analog output, comprehensive input isolation, and robust RS-485 MODBUS communication. It calculates absolute position data directly from a Synchro Transmitter and triggers programmable alarms during key operating conditions, ensuring operations teams are proactively alerted to scheduled maintenance needs.\u003c\/p\u003e\n\n\u003ch3\u003eKey Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAbsolute Position Monitoring:\u003c\/strong\u003e Accurately measures and relays absolute tap position directly from a connected Synchro Transmitter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePredictive Maintenance:\u003c\/strong\u003e Tracks physical LTC movement continuously to help operators schedule required service prior to failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgrammable Alarms:\u003c\/strong\u003e Configurable alerts tailored to key operating parameters and environmental thresholds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eData Integration:\u003c\/strong\u003e Outfitted with an isolated input, standard RS-485 MODBUS communication, and 4-20 mA analog output for straightforward integration into existing SCADA or facility control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth\u003eManufacturer\u003c\/th\u003e\n      \u003ctd\u003eFranklin Electric \/ INCON\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel\u003c\/th\u003e\n      \u003ctd\u003e1250-LTC-4-I-M\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eAnalog Output\u003c\/th\u003e\n      \u003ctd\u003e4-20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCommunication Interface\u003c\/th\u003e\n      \u003ctd\u003eRS-485 MODBUS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInput Type\u003c\/th\u003e\n      \u003ctd\u003eIsolated Synchro Transmitter Input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eMonitoring Metric\u003c\/th\u003e\n      \u003ctd\u003eAbsolute Position Tracking\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of analog output does the Franklin 1250-LTC-4-I-M monitor provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This specific configuration (1250-LTC-4-I-M) provides a standard 4-20 mA analog output along with RS-485 MODBUS communication capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the monitor determine the exact LTC position?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1250-LTC calculates the absolute position directly by interpreting the mechanical input derived from an attached Synchro Transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this unit have isolated inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 1250-LTC-4-I-M features input isolation to protect internal circuitry and ensure precise data gathering from the transmitter.\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/855X118-specsheet.pdf?v=1793740936\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct PDF 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/855X118-specsheet_4514b157-a41a-47c6-a5f8-d3e7ed4c8d9c.pdf?v=1793740948\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct PDF 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/855X118-specsheet_3d1b455c-5ebe-4a1c-8bf5-a71f5f5d38c4.pdf?v=1793740962\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct PDF 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/855X118-specsheet_b9fef637-e8bf-4504-88aa-7d61e10f1989.pdf?v=1793740976\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct PDF 4\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Franklin Electric","offers":[{"title":"Default Title","offer_id":50828705103970,"sku":"855X118","price":6548.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/855x118_pli-franklin-electric-grid-1250-ltc-4-i-m_jpg.webp?v=1793741012","url":"https:\/\/www.fiberoptics4sale.com\/products\/franklin-1250-ltc-4-i-m-load-tap-changer-monitor-4-20ma-i-m","provider":"Fosco Connect","version":"1.0","type":"link"}