Overview
The FiberXP SC/APC to LC/APC single-mode fiber optic patch cable is a simplex, bend-insensitive jumper designed for high-precision network connectivity. Engineered to maintain signal integrity in compact spaces, this cable features a 2.0mm PVC jacket and angle-polished connectors (APC) to minimize back reflectance.
Ideal for data centers, enterprise networks, and telecommunications environments, this patch cable ensures consistent performance during fiber routing. Each cable is 100% optically tested to verify low insertion loss and high return loss performance, with actual test data included for quality assurance.
Key Features
-
Bend-Insensitive Fiber
Optimized to reduce signal loss in tight-radius routing and compact enclosures. -
Angle-Polished Connectors (APC)
Features SC/APC and LC/APC connectors for superior return loss and minimized back reflection. -
Simplex Design
Configured as a single-fiber cable for dedicated signal transmission paths. -
Insertion Loss Performance
Verified testing ensures insertion loss is typically less than 0.3dB. -
Return Loss Performance
Engineered for >65dB return loss, supporting high-fidelity signal transmission. -
Durable Construction
Equipped with a 2.0mm PVC jacket for reliable protection in standard operating environments. -
Quality Assurance
Each cable is factory-tested, with documentation provided to verify optical metrics.
Applications
- Data center fiber interconnects
- Telecommunications network distribution
- Enterprise LAN/WAN backbones
- FTTH (Fiber to the Home) installations
- High-density fiber optic patching
Technical Specifications
| Specification | Value |
|---|---|
| Model | PCA53SSP003-BI |
| Connector A | SC/APC |
| Connector B | LC/APC |
| Fiber Mode | Single Mode |
| Cable Type | Simplex |
| Insertion Loss | < 0.3dB |
| Return Loss | > 65dB |
| Cable Length | 3 meters |
| Jacket Material | PVC |
| Jacket Diameter | 2.0mm |
Frequently Asked Questions
What is the primary benefit of bend-insensitive fiber?
Bend-insensitive fiber is engineered to prevent significant signal leakage when the cable is routed around sharp corners or installed in high-density fiber management systems.
Are these cables tested before shipment?
Yes, every patch cable is 100% optically tested, and the measured test data is included with the product for verification.
Can I use this with standard UPC connectors?
No, this cable uses APC (Angle-Polished) connectors. APC and UPC connectors are not physically compatible and should not be mated.
What does the return loss value indicate?
A high return loss of >65dB indicates that very little light is reflected back toward the source, which is critical for maintaining performance in high-speed, sensitive network applications.
Is the cable simplex or duplex?
This is a simplex cable, meaning it contains a single fiber strand for one-way signal transmission.