Franklin 1932 AC Line Power Conditioner
The Franklin Electric 1932 AC Line Power Conditioner is engineered to deliver highly regulated line voltage specifically for use with 1250-LTC or 1250B Programmable Position Monitors and their associated synchro transmitters. By actively filtering harmonic noise and eliminating transient spikes, this unit guarantees a clean, stable output critical for precise grid monitoring applications.
Key Features & Capabilities
- Precision Regulation: Provides a clean 115 VAC output (±3%) for sensitive position monitoring equipment.
- Advanced Protection: Integrated lightning arrestors and surge protection safeguard critical infrastructure from transient voltage spikes.
- Harmonic Filtering: Stabilizes operation and enhances monitor accuracy by actively filtering harmonic noise from the AC line.
- Industrial Temperature Rating: Built for harsh environments with a wide operating range of -13°F to 158°F (-25°C to 70°C).
Technical Specifications
| Input Voltage | 105 to 135 VAC @ 60 Hz |
|---|---|
| Output Voltage | 115 VAC @ 60 Hz (±3%) |
| Load Range | 10 VA (Minimum) to 25 VA (Maximum) |
| Operating Temperature | -25°C to 70°C (-13°F to 158°F) |
| External Fuse Requirement | 5 Amp (Max) – Not supplied, required for operation |
Frequently Asked Questions
Q: What position monitors is the Franklin 1932 compatible with?
A: This AC line power conditioner is designed specifically for use with the Franklin 1250-LTC and 1250B Programmable Position Monitors alongside their synchro transmitters.
Q: Is the required fuse included with this power conditioner?
A: No, an external 5 Amp (Max) fuse is required for operation but is not supplied with the unit.
Q: Does the unit protect monitoring equipment against power surges?
A: Yes, the conditioner includes integrated lightning arrestors and surge protection to prevent damaging transient spikes from reaching your sensitive hardware.