Overview
The Tempo Communications LCAPC BH Angled-Polish Connector Bulkhead Fiber Inspection Tip is designed for use with the FIP100 Automated Fiber Inspection Probe. This specialized adapter tip facilitates precise end-face inspection of LC/APC bulkhead connectors.
By providing a stable interface, this tip ensures clear and accurate capture of fiber end-face imagery. It is an essential component for technicians performing installation and maintenance of fiber optic networks, helping to verify connector condition and ensure optimal signal transmission.
Key Features
-
Compatibility
Designed specifically for integration with the FIP100 Automated Fiber Inspection Probe system. -
Precision Interface
Optimized to securely seat within LC/APC bulkhead adapter ports for consistent alignment. -
Angled Polish Support
Engineered to accommodate the geometry of LC/APC (Angled Physical Contact) connectors. -
Field Durability
Constructed to withstand the rigors of frequent fiber optic network installation and maintenance tasks. -
Easy Attachment
Designed for quick and simple swapping on the FIP100 probe platform, reducing downtime during field inspection. -
End-Face Visibility
Facilitates clear optical access to fiber cores and cladding to identify scratches, pits, or contamination.
Applications
- Fiber optic cable installation
- Network maintenance and troubleshooting
- Fiber optic connector inspection
- Data center cabling verification
Technical Specifications
| Specification | Value |
|---|---|
| Manufacturer | Tempo Communications |
| Model | LCAPC BH |
| Part Number | 470X106 |
| Connector Type | LC APC |
| Application | Bulkhead Adapter |
| Compatibility | FIP100 Automated Fiber Inspection Probe |
Frequently Asked Questions
What probe is this tip designed for?
This tip is specifically designed for the Tempo FIP100 Automated Fiber Inspection Probe.
Can this be used for LC/UPC connectors?
No, this tip is engineered for LC/APC (angled) connectors. Inspecting UPC connectors with an APC tip may produce inaccurate results.
Is this tip for bulkhead or patch cord inspection?
This model is a bulkhead adapter tip, intended for inspecting connectors mounted in panels or adapters.
How do I change the tips on my FIP100?
The FIP100 tips are designed to be easily removed and attached to the probe head, facilitating quick transitions between different connector types.
Does this include the probe?
No, this is an accessory tip only; the FIP100 probe is sold separately.